welding is not permitted.

解释: 启动焊接信号后无接触信号,导致无法焊接文章源自好焊孙辉博客 https://www.sunhui.me好焊孙辉-https://www.sunhui.me/weldgyzb/autoweld20241129.html

Cause: • No stud in collet.文章源自好焊孙辉博客 https://www.sunhui.me好焊孙辉-https://www.sunhui.me/weldgyzb/autoweld20241129.html

原因:  夹套里没有焊钉文章源自好焊孙辉博客 https://www.sunhui.me好焊孙辉-https://www.sunhui.me/weldgyzb/autoweld20241129.html

  • Feeder without weld studs.

送料器里没有焊钉文章源自好焊孙辉博客 https://www.sunhui.me好焊孙辉-https://www.sunhui.me/weldgyzb/autoweld20241129.html

  • Stabilizer incorrectly set or contaminated.

支撑脚或喷嘴调整不当或太脏文章源自好焊孙辉博客 https://www.sunhui.me好焊孙辉-https://www.sunhui.me/weldgyzb/autoweld20241129.html

  • Weld circuit interrupted.

焊接回路中断文章源自好焊孙辉博客 https://www.sunhui.me好焊孙辉-https://www.sunhui.me/weldgyzb/autoweld20241129.html

  • Weld head fault (i.e. weld head got jammed).

焊头故障(例如:焊头被卡住了)文章源自好焊孙辉博客 https://www.sunhui.me好焊孙辉-https://www.sunhui.me/weldgyzb/autoweld20241129.html

  • Collet defective.

夹持器损坏了文章源自好焊孙辉博客 https://www.sunhui.me好焊孙辉-https://www.sunhui.me/weldgyzb/autoweld20241129.html

Remedy: • Remove loading fault.文章源自好焊孙辉博客 https://www.sunhui.me好焊孙辉-https://www.sunhui.me/weldgyzb/autoweld20241129.html

措施: 排除送钉故障文章源自好焊孙辉博客 https://www.sunhui.me好焊孙辉-https://www.sunhui.me/weldgyzb/autoweld20241129.html

  • Check adjusting of stabilizer.

检查支撑脚或喷嘴的调整状态

  • Check welding circuit.

检查焊接回路

  • Stud feeding.

送一次钉

  • Repeat weld cycle.

重复一次焊接

  • Replace collet.

更换夹持器

  • Notify service engineer!

专业人员处理

                                                                                                                        

Fault 3: “Weld tool not in back position“

故障 3 :焊头没有在焊接位置

Explanation: Proximity switch for back position not configured, defective or power supply missing.

解释:焊接位置的接近开关没有被盖住或接近开关被损坏或者没有电压

Cause: • Drop in compressed-air supply.

原因: 压缩空气供应气压不足

  • Cable package defective.

管线总成损坏

  • Monitoring time after welding was exceeded.

焊接之后的检测时间超差

  • Weld head defective.

焊头损坏

  • Feeder defective.

送料器损坏

  • Collet welded to work surface.

把夹持器焊在工件表面了

Remedy: • Check compressed air.

措施:  检查压缩空气供应装置

  • Check cable package.

检查管线总成

  • Check weld head - slide rail motion.

检查焊头运动滑轨

  • Check or replace weld head.

检查或更换焊头

  • Check feeder.

检查送料器

  • Check feeder fuses F1-F3.

检查送料器保险丝F1-F3

  • Reset fault.

故障复位

  • Replace collet.

更换夹持器

  • Notify service engineer!

专业人员处理

                                                                 

Fault 5: “Weld procedure sequence fault“

故障 5 :焊接程序顺序故障

Explanation: Due to a malfunction the weld sequence is not terminated correctly.

解释:由于一个错误功能使焊接过程没有按照程序进行到底

Cause: • Feeder or SMPS malfunction.

原因:  送料器或电源故障

Remedy: • Reset fault.

措施:  故障复位

  • Check welding (if necessary repeat welding).

检查焊接(重新焊接)

  • Notify service engineer!

专业人员处理

                                                                                                                        

Fault 6: “Program no selected“

故障 6  缺少程序

Explanation: The weld unit does not detect any program number.

解释: 焊接单元不识别程序号码

Cause: • Program no. is 0.

原因: 程序号码为0

  • Transfer signal has not been set.

没有设置接受信号

  • Data line defective.

数据线被损坏了

Remedy: • Customer interface (or interface program) must be verified.

措施: 检查用户接口(或接口程序)是否编写

  • Notify service engineer!

专业人员处理

                                                                                                                       

Fault 7: “Program not active“

故障 7  程序没有激活

Explanation: The selected weld program is not active and therefore cannot be executed.

解释: 由于被选择的焊接程序没有被激活,因此无法实施焊接

Cause: • Weld unit incorrectly programmed.

原因: 焊接单元程序编写错误

  • Fault customer control.

用户控制端错误

  • Data line defective.

数据线被损坏了

Remedy: • Check weld program and activate or select an active weld program.

措施:  检查焊接程序并激活或者选择一个已经激活的程序

  • Notify service engineer!

专业人员处理

                                                    

Fault 13: “SMPS: Lift fault“

故障 13    电源:没有拉弧

Explanation: Weld unit is unable to identify lift via measurement lines.

解释:焊机通过它的测量线不能确定拉弧过程

Cause: • Incorrectly sequence of lift movement.

原因: 拉弧过程的顺序不正确

  • Weld conditions prohibit lift.

焊接条件阻碍了拉弧

  • Cable package defective.

管线总成损坏

  • Weld head defective.

焊头被损坏

  • Defective feeder.

送料器被损坏

  • Internal process cycle fault.

设备内部运行故障

Remedy: • Check weld conditions.

措施: 检查焊接条件

  • Check weld head.

检查焊头

  • Check feeder.

检查送料器

  • Stud feeding.

送一次钉

  • Check feeder connection.

检查送料器连接线

  • Repeat weld cycle.

重复一次焊接

  • Forced WC.

启动焊接完成信号

  • Notify service engineer!

专业人员处理

                                                           

Fault 15: “Drop down timeout“

故障 15  下落时间超时

Explanation: Max. drop time was exceeded and welding was stopped.

解释: 下落时间超出最大允许值,焊接被中断

Cause: • Air gap incorrectly adjusted.

原因: 间隙调整错误

  • Weld circuit resistance too high.

焊接回路电阻过高

  • Measurement line-ground missing.

没有连接地线测量线

  • SKK / PK defective.

自动焊头或焊枪损坏

Remedy: • Reset fault.

措施: 故障复位

  • check measurement line (if necessary, reduce weld circuit resistance)

检查测量线(降低焊接回路电阻值)

  • Check setting of SKK- / PK.

检查自动焊头或焊枪状态

  • Notify service engineer!

专业人员处理

                                                                                                                       

Fault 16: “Open circuit, no arc“

故障 16  空载焊接

Explanation: Extinguishing of the arc during weld, resp. the weld current is below I =80A.

解释: 焊接过程中拉弧被断开,或焊接回路电流小于80A

Cause: • Air gap too large.

原因: 间隙过大

  • Gun was removed at the beginning of the weld.

焊枪在开始焊接时被提起

  • Extremely impure work surface.

焊接表面油污太多

  • Fault SMPS.

电源故障

Remedy: • Repeat weld cycle.

措施: 重复一次焊接

  • Stud feeding.

送一次钉

  • Check adjusting of the weld gun.

检查焊枪的调整

  • Check welding conditions.

检查焊接条件

  • Check work piece conditions.

检查工件表面

  • Notify service engineer!

专业人员处理

                                                                                                                    

Fault 17: “Measurement line broken“

故障 17  测量线中断

Explanation: Measurement line signal not any longer detected.

解释: 测量线信号没有被捕捉到

Cause: • Measurement line broken or incorrectly connected.

原因: 测量线损坏或连接错误

  • Reversed measurement line-ground and measurement line.

地线测量线和测量线接反了

  • SOW power failure.

和工件的接触电压中断

  • Weld line interrupted.

焊接电缆中断

博主现就职于深圳市鸿栢科技实业有限公司, 从事焊接设备营销推广及销售工作15年,拥有丰富的行业经验及资源,致力于中国汽车焊接设备营销推广,欢迎广大汽车制造焊接工艺与车身新材料连接技术研究的朋友们一起探讨新技术、新设备。  
       螺柱焊机,点焊机,电极帽修磨机及各种焊接设备备件易损件,备件采购联系:18682260315

继续阅读
weinxin
18682260315
已复制
孙辉

6948269

添加作者微信:18682260315

微信扫一扫,或点击二维码复制微信号

广告也精彩
孙辉
  • 免责声明:根据公开数据整理,版权归原作者所有,仅供学习交流,不代表本站立场,
    如有侵犯版权, 请及时联系邮箱hui@36kp.com
  • 转载请务必保留本文链接:https://www.sunhui.me/weldgyzb/autoweld20241129.html
广告也精彩
匿名

发表评论

匿名网友
:?: :razz: :sad: :evil: :!: :smile: :oops: :grin: :eek: :shock: :???: :cool: :lol: :mad: :twisted: :roll: :wink: :idea: :arrow: :neutral: :cry: :mrgreen:
确定

拖动滑块以完成验证